Primary tabs

FREE SHIPPINGFree shipping on all orders over 100000 INR.

Oxygen Scavenger OxyGuard S

0
No votes yet
SKU::RXSOL-34-6119-250

Product Qty Per Unit: 
250.00
Product usage unit: 
Kg.Liq

Negotiate Price

Category: 
RIGS Oil Field-34
Generic Name: 
Used as Oxygen Scavanger for Drilling Rigs

Powerful concentrated corrosion inhibitor acts as oxygen scavengers used to effectively remove dissolved OXYGEN

Product Description: 

This is most common oxygen treatment as a scavengers used to effectively remove dissolved  OXYGEN from your feedwater. By the presence of dissolved oxygen in system, corrosion and pitting caused on metal surface. Removes dissolved oxygen, By acting as an oxygen scavenger.

A fast-acting, catalyzed sodium sulphite (Na₂SO₃) oxygen scavenger for low- and medium-pressure boiler systems. The product reacts stoichiometrically with dissolved oxygen to prevent corrosion in boilers, feed lines, and condensate systems by converting oxygen to inert sulfate.

Product Application: 
Key Areas of Application of Oxygen Scavenger OxyGuard-S
  • Oxygen removal in low/medium-pressure boilers (typically up to ~65 bar; usage above this pressure is uncommon due to potential sulfate/solids carryover).
  • Hot standby protection to prevent pitting during idle periods i.e. Oilfield Application.
  • Feedwater & deaerator outlets where residual O₂ must be suppressed rapidly.
Product Procedure: 

Reaction (overall):
Na₂SO₃ + ½ O₂ → Na₂SO₄

Catalyst accelerates the reaction at lower temperatures and shorter residence times (e.g., in deaerator outlets and feedwater lines)

Power of Oxygen Scavenger OxyGuard-S: powerful stoichiometry: ~7.88 mg/L Na₂SO₃ per 1 mg/L dissolved O₂.
With safety factor (process variability, kinetics), dose 10–12 mg/L Na₂SO₃ per 1 mg/L O₂.
 
Typical operating targets (LP/MP boilers):
 
  • Deaerator outlet O₂: ≤ 7–10 ppb (if DA present)
  • Sulfite residual in boiler water:
  • Normal operation: 20–40 mg/L as Na₂SO₃
  • High risk / wet lay-up: 60–100 mg/L as Na₂SO₃
  • pH (feedwater/boiler): follow your internal treatment program (commonly FW pH 8.5–9.2; boiler water pH 10.5–11.5 depending on pressure).
 
Where to feed:
  • Preferably deaerator storage section or feedwater line upstream of economizer to ensure complete O₂ removal before the boiler.

Example Dose Calculation

Feedwater DO = 0.10 mg/L (100 ppb) at 20 m³/h.
Stoichiometric Na₂SO₃ = 0.10 × 7.88 = 0.788 mg/L.
With 1.3× safety factor → ~1.0 mg/L Na₂SO₃.
At 20 m³/h → 20 g/h Na₂SO₃ (as pure).
Using 38% liquid: 20 / 0.38 ≈ 52.6 g/h (~40 mL/h) (SG 1.32 ⇒ ~30 mL/h by mass; verify on site).
Fine-tune to maintain target sulfite residual in boiler.

Product Note: 
Benefits of using Oxygen Scavenger OxyGuard-S
  • Rapid kinetics with catalyst—effective even at moderate temperatures.
  • Reliable corrosion protection of pre-boiler & boiler circuits.
  • Cost-effective vs. volatile scavengers for LP/MP systems.
  • Easy control by simple sulfite residual testing.
  • Compatible with most phosphate/polymer internal treatments.
Product Technical Specification: 
Property Specification
Appearance Clear to pale straw liquid
Specific gravity @ 25 °C ~1.30 – 1.34 (depends on strength)
pH (neat) 8.5 – 10.5 (stabilized alkaline)
Odor Faint sulfurous
Freeze point < 0 °C (varies with strength)
Solubility Completely miscible with water
Product pack size: 
SCAVENGER OXYGEN, OXYGEN SCAVENGER, WATER-BASED DISSOLVED OXYGEN SCAVENGER LIQUID, WATER SOLUBLE SCAVENGER available in 250 Kg Liquid Drum.
Product alias: 
<p> Oxygen Scavenger Sodium Sulphite, OXYGEN SCAVENGER SCAV TREAT</p>

RXSOL Oxygen Scavenger is  soluble in water. It is noncombustible. It is corrosive to aluminum. It is a strong irritant to skin and mucous membranes. It is toxic by skin absorption.

Oxygen Scavenger – Sodium Sulphite

Product Description:

Oxygen Scavenger – Sodium Sulphite is a highly effective oxygen scavenging chemical formulated to remove dissolved oxygen from boiler feed water, injection water, and industrial water systems. It rapidly reacts with dissolved oxygen, preventing corrosion in pipelines, boilers, heat exchangers, storage tanks, and water injection systems.

The product is widely used in the oil & gas, power generation, petrochemical, refinery, and water treatment industries to maintain low dissolved oxygen levels and protect critical equipment from oxygen-induced corrosion.

Key Features

  • Rapidly removes dissolved oxygen from water.

  • Prevents corrosion in boilers and water injection systems.

  • Protects pipelines, heat exchangers, and storage tanks.

  • Improves equipment reliability and service life.

  • Suitable for high-pressure and low-pressure boiler systems.

  • Easy to dose and compatible with most water treatment programs.

  • Reduces maintenance and operating costs.

Applications

  • Boiler Feed Water Treatment

  • Water Injection Systems

  • RO Permeate Treatment

  • Condensate Systems

  • Industrial Water Treatment

  • Oil & Gas Production Facilities

  • Power Plants

  • Petrochemical Industries

Typical Specification

Property Specification
Chemical Name Sodium Sulphite
Appearance Clear Liquid / White Powder (as applicable)
Active Content As per customer specification
Function Oxygen Scavenger
Application Boiler & Injection Water Treatment

Performance Requirement

  • Maintains dissolved oxygen (DO) below the specified operating limit.

  • Effectively prevents oxygen-induced corrosion.

  • Suitable for continuous dosing in industrial water treatment systems.

  • Compatible with membrane and boiler water treatment programs (where applicable).

 

Oxygen Scavenger Sodium Sulphite, Sodium Sulphite Oxygen Scavenger, Boiler Water Oxygen Scavenger, Injection Water Treatment Chemical, Dissolved Oxygen Remover, Boiler Water Treatment Chemicals, Corrosion Prevention Chemical, Industrial Water Treatment Chemicals, Sodium Sulphite Supplier, Oxygen Scavenger for Water Injection.

Remarks: 

Control test methods:

  • Residual sulfite by iodometric titration (express as mg/L Na₂SO₃).
  • Dissolved oxygen by luminescent/optical or membrane DO analyzer at DA outlet.
 
Use Guidelines
 
  • Start with calculated stoichiometric dose + safety factor based on measured DO.
  • Adjust pump to maintain target sulfite residual in the boiler drum.
  • Increase dose for intermittent operation, cold feeds, or high leakage air into DA.
  • For wet lay-up, raise sulfite residual to upper range and circulate periodically.
 
Compatibility
 
  • Compatible with phosphates, chelants (as per program limits), and dispersant polymers used for scale/sludge control.
  • Avoid co-feeding with oxidizing biocides (e.g., chlorine) as they will consume sulfite.
  • Downstream of RO systems, sodium bisulfite is typically preferred for dechlorination; this product is not intended as an RO dechlorinator.

Oxygen Scavenger supplier and exporter from Mumbai, Chennai, Kolkata, Visakhapatanm, Gandhidham, Fujairah, Sharjah, Dubai, Abudhabi, Gulf Middle East, Muscat Barka Sohar Oman, Nairobi Kenya Africa, Canada


Product Delivery Locations: 
Kattupalli Port ( L & T Shipbuilding Limited shipyard ), Ennore Port ( Coromondel International Limited Port Area ), Chennai Port, Mugaiyur port, Thiruchopuram port, Silambimangalam Shipyard, Parangipettai port, PY-03 Oil Field, Kaveri port, Vanagiri port, Thirukkadaiyur port, Thirukkuvalai port, Punnakkayal port, Udangudi port, Manappad port, Koodankulam port, Chettinad Tharangambadi Port, Mathur SIDCO Industrial area, Sipcot Industrial Park Malayambakkam